You did your best to avoid contamination, but the trouble happened. What to do?
You can try to limit the contamination to the other cultured cells.
And what about the contaminated culture?
The best and safest way to prevent further disasters is to throw away the contaminated cell culture.
However, in some cases it may be absolutely necessary to keep the culture, for example if it is irreplaceable.
If the culture is contaminated with mold and yeast, an antimycotic should be used to try to eliminate the problem.
Routinely used antibiotics such as penicillin / streptomycin (pen / strep), gentamicin and kanamycin are NOT effective against fungi or molds.
The two most common antifungal agents used in cell cultures that are effective against fungi or molds are
- amphotericin B (Fungizone)
- mycostatin (Nystatin)
AMPHOTERICIN B
- It interferes with the cell membrane permeability of sensitive fungi by binding sterols.
- Since the membranes of eucharitic cells also contain sterols, amphotericin is also toxic for the cells.
Amphotericin B must be used very limitedly (at the lowest possible concentration) and for the time strictly necessary.
- It can be used in media at final working concentrations between 0.25ug / ml and 2.5ug / ml
- It is soluble in DMSO and, once dissolved, you should store it in the -20 ° C. There are also ready solutions of amphotericin solubilized in water.
- The stability at 37 ° C, therefore in the culture medium in use, is 3 days
NYSTATIN
- It also interferes with the permeability of the cell membrane of sensitive fungi by binding to sterols, thus giving rise to the same toxicity problems as amphotericin.
- Nystatin is a colloidal suspension rather than a solution. you have to mix it thoroughly before its addition to cell culture media.
When nystatin is in the medium and seen under a microscope, it will appear as small crystal-like particles, don’t think they are bacteria!
- It must be stored in -20 ° C and the stability at 37 ° C, therefore in the culture medium in use, is 3 days.
- Use nystatin at final working concentrations between 100U / ml and 250U / ml.